Environmental Control Dry Air Glove Box,Low Humidity Dry Air Glove Box

CDA Glove Box enables precision work in a fully controlled dry environment.

CDA Glove Box - CDA Glove Box enables precision work in a fully controlled dry environment.
  • CDA Glove Box - CDA Glove Box enables precision work in a fully controlled dry environment.

CDA Glove Box

BX128(A)-CDA

Environmental Control Dry Air Glove Box,Low Humidity Dry Air Glove Box

The Bossmen CDA Glove Box is designed for small-scale processing and closed-environment operations in laboratories, offering excellent dust-proof functionality and customizable humidity control ranges to ensure a stable and precise working environment.

This product meets standard specifications and can be custom-sized to suit specific needs, providing optimal workspace for both single and multi-user operations.

The Bossmen CDA Glove Box provides a cleaner working environment for various precision tasks, making it highly suitable for microscopy, precision instrument operation, BGA, LCD, and other SMD component processing, mold assembly, and applications in high-demand environments such as semiconductor, crystal, and optical lens processing, ensuring that every process achieves optimal precision.

Features
  • Adjustable Humidity: Adjustable between 1%-60% RH.
  • Built-in High-Efficiency Logging Function: Stores up to 11,900 temperature and humidity records.
  • Configurable Data Collection Intervals: Adjustable time intervals ranging from 1 to 240 minutes.
  • Flexible Collection Time Settings: Detailed setup by year, month, day, hour, and minute.
  • Data Download and Storage: Data can be downloaded to a computer via RS232 interface and stored in a quality assurance record format.
  • Supports Database File Formats: Can be exported in Excel, PDF, and other formats.
  • Dedicated Monitoring Software: Includes Bossmen View monitoring software for precise data tracking and analysis.
  • Temperature and Humidity Out-of-Range Alarm: When set humidity conditions are exceeded, users can configure activation ranges and conditions.
  • Alarm Mode: The buzzer sounds at 90 dB to alert users to abnormal equipment status, with flashing digits providing a visual cue to enhance the alarm's effect. Both the buzzer and flashing digits can trigger simultaneously to increase visibility and alertness to equipment issues.
Application
  • Microbiological Experiments: In microbial cultivation or aseptic operations, the humidity-controlled glove box provides a dry, sterile environment, effectively preventing moisture from affecting media or samples, and maintaining stable experimental conditions.
  • Biochemical Experiments: Many chemicals and reagents are sensitive to humidity. The humidity-controlled glove box ensures that instruments and reagents are not affected by moisture, ensuring the accuracy of reactions.
  • Materials Science Research: In research involving high-precision materials (such as semiconductors, optical materials, etc.), moisture can negatively affect material properties. The humidity-controlled glove box maintains a stable dry environment, preventing deliquescence or performance changes in materials.
  • Pharmaceutical Experiments: During drug development, certain drugs and raw materials are extremely sensitive to humidity and may degrade or deteriorate. The humidity-controlled glove box provides a stable, dry storage environment to effectively prevent these issues.
  • Cleanroom Operations: When testing or assembling high-end electronic products (such as displays, precision electronic components), the humidity-controlled glove box provides a dust-free, controlled humidity environment, helping to prevent moisture or dust from damaging sensitive components.

These experiments require a strictly controlled environment to ensure the accuracy of results and the safety of items. The humidity-controlled glove box provides an ideal dry, contamination-free workspace.

Product Specifications
ModelDry Air Glove Box
BX128(A)-CDA
Control ModuleDry Air Control Unit
Humidity Control Range1% RH – 60% RH
External Dimensions (mm)W700 × D600 × H500
Internal Dimensions (mm)W680 × D470 × H480
Cabinet Material10 mm Transparent Acrylic
Door Opening Size (mm)W350 × H350
Transfer Port Size (mm)W300 × H300
Glove Port Diameter (mm)Ø150
Humidity Display Range0% RH ~ 99.9% RH
Temperature Display Range1 ~ 60°C
Power Supply100–240 VAC / 50–60 Hz
Gallery
Related Products
20% ~ 60% RH Glove Box - 20% ~ 60% RH Glove Box for lab use, with dust-proof function and adjustable humidity range.
20% ~ 60% RH Glove Box
BX128(A)

The Bossmen 20% ~ 60% RH Glove Box is designed for small-scale item processing and closed-environment...

Details
1% ~ 40% RH Glove Box - Low humidity dustproof glove box with adjustable humidity control.
1% ~ 40% RH Glove Box
BX128L(A)

The low humidity glove box is a high-performance moisture control solution specifically designed...

Details
Nitrogen Glove Box - Nitrogen Glove Box ensures oxygen-free, inert gas environment for sensitive materials.
Nitrogen Glove Box
BX128(A)-N2

In many scientific research and industrial applications, the operating environment for materials...

Details
CDA Glove Box - CDA Glove Box enables precision work in a fully controlled dry environment.
CDA Glove Box
BX128(A)-CDA

The Bossmen CDA Glove Box is designed for small-scale processing and closed-environment operations...

Details
Moisture Control glove box - Moisture Control Glove Box provides a dust-free, temperature and humidity-controlled environment for sensitive material handling.
Moisture Control glove box
BX128(A)-SH

The Bossmen Moisture Control Glove Box is a precision device designed for laboratories and high-tech...

Details
Standard Glove Box - Standard Glove Box provides a contamination-free environment for experiments with no humidity requirements.
Standard Glove Box
BX128(A)-CA

The Standard Glove Box is a simple yet powerful laboratory device, designed for applications...

Details

CDA Glove Box – Precision Humidity Control by BOSSMEN

The CDA Glove Box is designed to protect sensitive materials, electronics, and instruments from moisture damage. BOSSMEN integrates advanced humidity control systems to maintain stable RH levels, ensuring reliability in manufacturing, laboratories, and research facilities.

Engineered with precision and durability, the CDA Glove Box offers consistent performance for long-term storage and process environments. From cleanrooms to quality labs, BOSSMEN products help users reduce corrosion, oxidation, and ESD risks while maintaining compliance with strict environmental standards.

Discover how the CDA Glove Box enhances productivity and preservation in your workflow. Each unit reflects BOSSMEN’s thirty years of humidity control expertise, combining innovation, safety, and measurable value for industrial and laboratory applications.